Flow Sensors & Switches
Thermal-dispersion flow switches detect whether liquid or gas in a pipe is moving above a set point, then switch a relay. There is no paddle, no vane and no moving part in the flow path, so debris and scale do not jam the instrument. Our range covers the standard single set-point switch, a dual set-point version for alarm-and-trip duty, and a digital model that shows live flow velocity on an LED display. All three are fully sealed and rated IP67, with a wetted probe in SUS 316L. Where you need regulation rather than detection, the S400 controller closes the loop with a proportional valve.
What it measures
- Flow velocity
- Set-point crossing
- Volumetric flow (controller)
Available outputs
- Relay (SPDT)
- PNP / NPN
- 4–20 mA
4 models in this family
Sorted by typical duty — workhorse models first
Illustrative imageThermal Flow Switch
Single set-point
Thermal-dispersion flow switch with a single adjustable set-point, sealed all-in-one stainless body rated IP67 and 100 bar. Relay, PNP, NPN or 4–20 mA output, G1/2 thread as standard. No paddle and no moving part in the flow path, so scale and debris cannot jam it.
View specifications
Illustrative imageThermal Flow Switch
Dual set-point
Two independently adjustable set-points on one thermal flow switch, giving alarm and trip from a single instrument. Two potentiometers set the thresholds; red, yellow and green LEDs report which band the flow is in. IP68 sealed body, relay or PNP/NPN output, rated to 100 bar.
View specifications
Illustrative imageDigital Thermal Flow Switch
LED display
Thermal flow switch with a four-digit LED display showing live flow velocity, set by two front-panel keys rather than a screwdriver. Reverse-polarity, short-circuit and overload protected. Handles media up to 100 °C and pressures to 100 bar, sealed to IP67.
View specifications
Mass Flow Controller
Closed loop, 100–200 L/min
Closed-loop gas flow controller combining a thermal flow sensor and a normally-closed solenoid valve in one body. Three ranges — 100, 150 and 200 L/min — with ±1 % FS accuracy, 2 s response and 5–100 % control range. Swagelok or VCR fittings, ±15 V DC supply.
View specificationsOther product families
- Level Sensors & Transmitters17
- Pressure Transmitters & Controllers6
- Temperature Sensors & Transmitters10
- Ultrasonic Proximity Sensors7
- Laser Methane Detection3
- Linear Displacement Transducers5
- Analytical Instruments3
- Industrial IoT & Wireless Sensing5
- Motion, Photoelectric & Metering6
Looking across the whole catalogue instead? See all 66 models →
Need a model that is not in the catalogue?
Send us the medium, range, thread and output you need. Most custom configurations are quoted from the factory engineering desk rather than handed to a trading partner.