Factory-direct manufacturer · Xiamen, China · Exporting worldwide

Flow Sensors & Switches

HSM20 Thermal Flow Switch

Dual set-point

Request a quote

HSM20 technical data

Measurement

Measuring range — water
0–5 m/s
Measuring range — oil
0–10 m/s
Measuring range — gas
0–20 m/s
Maximum pressure
100 bar
Temperature gradient
Max. 250 K/min
Thermal response time
≤ 12 s

Electrical

Supply voltage
DC 24 V / AC-DC 110 V / AC-DC 220 V
Current consumption
< 80 mA
Output
Relay, or PNP / NPN — two channels selectable
Adjustment
Dual potentiometer
Switch timing
ON typ. 2 s (1–13 s); OFF typ. 2 s (1–15 s)
Indication
Red = below set-point 1; yellow = above set-point 1; green = above set-point 2

Mechanical

Wetted material
SUS 316L
Process connection
G1/2″ standard, others to order
Medium temperature
−20 to +80 °C (high-temperature version available)
Ingress protection
IP68

Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.

Request the PDF datasheet →

Flow Sensors & Switches

HSM20Thermal Flow Switch

Dual set-point

Two independently adjustable set-points on one thermal flow switch, giving alarm and trip from a single instrument. Two potentiometers set the thresholds; red, yellow and green LEDs report which band the flow is in. IP68 sealed body, relay or PNP/NPN output, rated to 100 bar.

Engineering reply · Evaluation samples available · Custom ranges built to order

  • Two independent set-points — warning and trip from one probe
  • Dual potentiometer adjustment, set accurately in the field
  • Three-colour LED band indication readable at a distance
  • IP68 sealed body for washdown and wet locations
  • Upgrade path from conventional single-point flow switches

How it works

The HSM20 is the HSM10 with two set-points instead of one. Two potentiometers are adjusted independently, so you can set a low threshold that raises a warning and a second threshold that trips the plant, from the same probe. Three indicator states — red below the first set-point, yellow above the first, green above the second — let an operator read the flow band from across the room without a display or a control system. The all-in-one sealed construction is rated IP68 rather than IP67, so the body survives washdown and temporary flooding. It uses the same thermal-dispersion principle and the same treated 316L probe as the rest of the range, which means the same immunity to fouling and the same absence of moving parts.

Typical applications

  • Cooling circuits needing both a warning and a shutdown threshold
  • Pump protection where a second stage must isolate the drive
  • Process lines with a minimum-flow alarm and a no-flow trip
  • Machine tools with independent coolant and lubrication monitoring

Not certain HSM20 is the right unit?

Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.

Same family

Other flow instruments

View the family →