Factory-direct manufacturer · Xiamen, China · Exporting worldwide

The catalogue is the starting point, not the limit

A non-standard thread, a longer probe, a different wetted material or a signal your control system already speaks — these are normal orders when the people quoting them are the people building them. Describe the duty and we will tell you what it takes.

What can change

Six parameters, set on the line

These are the variables the factory can move without becoming a different product. Anything outside them is a development project, and we will say so at the review stage rather than after the order.

Process connection

G1/2 and M20×1.5 are standard across most families. Other thread standards, flange and sanitary connections are machined to the drawing.

Threads · flanges · vessel connections

Probe length and diameter

Level and temperature probes are cut and welded to the vessel depth you specify, in diameters from 3 mm upward depending on the family.

3 mm – 5 m depending on principle

Wetted material

SUS 316L is the default. Where the medium attacks 316L, the probe, flange and seal material are selected against the medium rather than assumed.

316L · PEEK · custom wetted parts

Range and output

Measuring ranges are set at calibration, and output type — relay, PNP/NPN, 4–20 mA, 0–10 V or RS485 — is selected at order.

Relay · analogue · Modbus RTU

Housing and protection

Standard housings are IP65–IP67. Submersible assemblies are rated IP68, and explosion-proof housings are available for the gas and pressure ranges.

IP65 – IP68 · Ex housings

Temperature rating

High-temperature versions extend the medium ceiling beyond the standard 80 °C — for example the HSM flow switches and the TPS/TPT probes rated to 450 °C and above.

To 450 °C and higher on selected families

How it runs

From process conditions to a unit on the bench

  1. 01

    Send the process conditions

    Medium, temperature, pressure, pipe or vessel size, area classification, and the signal your control system accepts. A sketch or a photograph of the existing installation is more useful than a specification.

  2. 02

    Engineering review

    We come back with the nearest catalogue model, the changes needed, and any condition that the instrument cannot survive. If a catalogue item will do the job, we say so rather than quoting a special.

  3. 03

    Drawing and quotation

    For a non-standard build you receive a dimensioned drawing and a quotation before anything is cut. Changes to the drawing at this stage cost nothing.

  4. 04

    Build, calibrate, ship

    The unit is assembled and calibrated against the agreed specification, then supplied with its documentation. Repeat orders keep the same build parameters.

Common requests

What buyers usually ask for

If your requirement is on this list, it has been built before and there is a known answer.

  • Longer probe than the catalogue

    Level and temperature probes are made to vessel depth.

  • Thread the plant already uses

    Other thread standards, flange and vessel connections machined to drawing.

  • Aggressive medium

    Wetted material selected against the medium, not against the default.

  • Signal the PLC accepts

    Relay, analogue or RS485 selected at order.

  • Higher temperature

    High-temperature variants on selected flow and temperature families.

  • Hazardous area

    Explosion-proof housings on the gas and pressure ranges.

  • OEM marking

    Neutral or customer-branded labelling for machine builders.

  • Repeat batch

    Build parameters held for reorders so a second batch matches the first.

Fastest route for a custom enquiry

Email the process conditions and any drawing or photograph of the existing installation. That skips the form and puts the enquiry straight in front of an engineer.

Not sure whether you need a custom build? Start from the catalogue — most enquiries are answered by a standard model.

Need a model that is not in the catalogue?