Factory-direct manufacturer · Xiamen, China · Exporting worldwide

Level Sensors & Transmitters

HSM-VB106 / VB107 Microwave Level Switch

Non-contact through-wall

Request a quote

HSM-VB106 / VB107 technical data

Measurement

Minimum dielectric constant
≥ 1.5
Media
Solids and liquids
Foam sensitivity
None
Adjustment
Field-settable alarm point, live value shown

Electrical

Supply voltage
12–30 V DC
Current consumption
40 mA
Output
PNP or NPN
Maximum external load
20 mA
Ambient temperature
−40 to +85 °C

Mechanical

Wetted materials
PEEK and stainless steel
Medium temperature
115 °C standard; 150 °C with heat sink

Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.

Request the PDF datasheet →

Level Sensors & Transmitters

HSM-VB106 / VB107Microwave Level Switch

Non-contact through-wall

Microwave resonance switch that detects level through the vessel wall, so nothing protrudes into the process. Works on solids and liquids with dielectric constant above 1.5, ignores foam, and tolerates sticky conductive build-up. PEEK and stainless wetted parts, 115 °C standard or 150 °C with heat sink.

Engineering reply · Evaluation samples available · Custom ranges built to order

  • Unaffected by foam
  • Tolerates sticky and conductive build-up
  • Works on solids and liquids with εr ≥ 1.5
  • PEEK and stainless wetted parts for hygienic service
  • Set-point and live value visible on site
  • 115 °C standard, 150 °C with heat sink

How it works

The VB106/107 forms a high-frequency resonant circuit between its probe, its metal housing and the internal electronics. When medium covers the probe — or when the local dielectric constant changes — the resonant frequency shifts, and the unit compares the new frequency against your alarm setting. The consequence is a switch that does not care about foam, does not care about sticky or conductive build-up on the probe, and works on solids as well as liquids. Because it can be mounted to sense through the wall, it also serves hygienic vessels where a protruding probe would create a cleaning problem. PEEK and stainless are the wetted materials, so it holds up in food, pharmaceutical and industrial service.

Typical applications

  • Hygienic vessels where probes must not protrude
  • Powder and granule bin high-level detection
  • Pulp, slurry and coating media
  • Vessels with heavy foam on the surface

Not certain HSM-VB106 / VB107 is the right unit?

Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.