Factory-direct manufacturer · Xiamen, China · Exporting worldwide

Level Sensors & Transmitters

HWS10 Rod Float Level Switch

1–4 set-points

Request a quote

HWS10 technical data

Measurement

Measuring range
To customer specification
Set-points
1–4, positions to customer drawing
Media
Water, oil and similar liquids

Electrical

Contact rating
10 W
Contact resistance
Max. 0.2 Ω
Insulation resistance
100 MΩ at 500 V DC

Mechanical

Working pressure
0–6.3 MPa
Medium temperature
−20 to +150 °C
Rod diameter
Φ9 mm – Φ25 mm
Rod / float / flange material
SUS 304 or 316L
Terminal box
Aluminium alloy
Mounting
Flange or thread
Ingress protection
IP65

Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.

Request the PDF datasheet →

Level Sensors & Transmitters

HWS10Rod Float Level Switch

1–4 set-points

Discrete level switch with one to four magnetic reed points on a stainless guide rod. Passive dry contacts need no power supply, and the reed elements never touch the liquid. Rod diameter 9–25 mm, pressure to 6.3 MPa, temperature to 150 °C.

Engineering reply · Evaluation samples available · Custom ranges built to order

  • Passive dry contact — no power supply needed
  • Reed elements sealed inside the rod, never wetted
  • 1–4 independently positioned set-points
  • Rod and float in SUS 304 or 316L
  • Maintenance-free, no calibration

How it works

The HWS10 places one or more magnetic reed elements inside a stainless guide rod; a float carrying a permanent magnet rides up and down the rod and closes each reed as it passes. Because the contact is passive, the switch needs no supply — two wires are enough. The reed element is sealed inside the rod, so it never sees the medium; only stainless steel does. Up to four points can be positioned anywhere along the rod to your drawing, which makes one instrument do the job of several. Simple, with no electronics to drift and nothing to calibrate.

Typical applications

  • Tank high and low level alarm
  • Pump start/stop on sumps and reservoirs
  • Oil level monitoring in hydraulic reservoirs
  • Multi-point batching in mixing vessels

Not certain HWS10 is the right unit?

Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.

Same family

Other level instruments

View the family →