HS101-13 technical data

Measurement

Range
5–100 kN
Accuracy class
0.1 % FS
Rated output
1.2–2.0 mV/V
Zero output
±0.05 mV/V
Non-linearity
±0.1 % FS
Hysteresis
±0.1 % FS
Repeatability
±0.1 % FS
Creep (30 min)
±0.1 % FS
Temperature effect on sensitivity
±0.1 % FS per 10 °C
Temperature effect on zero
±0.1 % FS per 10 °C
Safe overload
150 % FS
Ultimate overload
200 % FS

Electrical

Input resistance
780 ± 20 Ω
Output resistance
700 ± 10 Ω
Insulation resistance
≥ 5000 MΩ at 50 V DC
Recommended excitation
5–10 V DC
Maximum excitation
15 V DC

Mechanical

Temperature compensation range
−10 to +40 °C
Operating temperature range
−20 to +60 °C
Cable
Φ5.0 × 3000 mm
Ingress protection
IP65

Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.

Request the PDF datasheet →

Motion, Photoelectric & Metering

HS101-13Tension / Compression Load Cell

5–100 kN

Strain-gauge load cell for 5–100 kN tension or compression, 0.1 % FS accuracy, 1.2–2.0 mV/V output, 150 % safe overload and 200 % ultimate. Stainless construction, IP65, 5–10 V DC excitation.

Engineering reply · Evaluation samples available · Custom ranges built to order

  • 5–100 kN range
  • 0.1 % FS accuracy class
  • 1.2–2.0 mV/V output
  • 150 % safe overload, 200 % ultimate
  • Temperature compensated −10 to +40 °C
  • IP65

How it works

A strain-gauge bridge bonded to a machined element: force deflects the element, the gauges change resistance, and the bridge outputs a millivolt signal proportional to load. The 0.1 % FS accuracy class and 1.2–2.0 mV/V sensitivity are the standard figures a weighing or force-control amplifier expects, so the cell drops into existing instrumentation without a special interface. Temperature compensation is applied over −10 to +40 °C, with sensitivity and zero drift both held to ±0.1 % FS per 10 °C.

Ordering notes

  • Images for this model are pending — request the current datasheet for dimensional drawings.

Typical applications

  • Web tension measurement
  • Press and stamping force
  • Crane and hoist load limiting
  • Material testing rigs

Not certain HS101-13 is the right unit?

Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.

Same family

Other motion & metering instruments

View the family →