Factory-direct manufacturer · Xiamen, China · Exporting worldwide

Pressure Transmitters & Controllers

PCC100 Pressure Transmitter Controller

5 relays, Φ100 mm case

Request a quote

PCC100 technical data

Measurement

Pressure range
−0.1 to 0, and 0 to 60 MPa
Sensor type
Diffusion silicon, ceramic piezoresistive or ceramic capacitive
Accuracy class
0.2 or 0.5
Overload pressure
1.5× full-scale
Sampling rate
4 readings per second
Display range
−1999 to 9999
Power supply effect
≤ 0.1 % FS

Electrical

Supply voltage
DC 24 V, AC 220 V ±15 %
Power consumption
≤ 5 W
Analogue output
4–20 mA / 0–10 or 20 mA / 0–5 or 1–5 V DC
Relay outputs
5 pairs
Relay rating
3 A at 250 V AC, 3 A at 30 V DC
Relay life
> 100 000 operations
A/D conversion
24-bit

Mechanical

Ambient temperature
−20 to +70 °C
Medium temperature
−20 to +80 °C
Storage temperature
−40 to +120 °C
Relative humidity
0–80 %
Housing material
Stainless steel + aluminium alloy
Connection
G1/2, M20×1.5 or to order
Ingress protection
IP65

Values are for the standard configuration. Ranges, threads, probe lengths and output types outside this table are available on request — the datasheet revision for a custom build is issued with the quotation.

Request the PDF datasheet →

Pressure Transmitters & Controllers

PCC100Pressure Transmitter Controller

5 relays, Φ100 mm case

The 100 mm version of the pressure controller: five relays, −0.1 to 60 MPa, 0.2 accuracy class, LED display, selectable analogue output. Fits the cut-out a 100 mm mechanical gauge leaves behind.

Engineering reply · Evaluation samples available · Custom ranges built to order

  • Φ100 mm case for tighter mounting
  • Five relay outputs
  • −0.1 to 60 MPa, 0.2 accuracy class
  • Storage to 120 °C
  • Selectable analogue output

How it works

Where space is tighter, the PCC100 provides the same five-relay control in a 100 mm case. It is the instrument to specify when a 150 mm gauge will not fit but the duty still calls for local display, alarms and an analogue signal to the control room. Storage temperature extends to 120 °C, useful in hot valve rooms.

Typical applications

  • Compact panels and skids
  • Hot valve rooms
  • Machine-level pressure interlock

Not certain PCC100 is the right unit?

Send the medium, range, process connection and the signal your control system accepts. We will confirm the model — or tell you which one fits better — before you commit to an order.

Same family

Other pressure instruments

View the family →